-40%
Hi-accuracy 0.1% Handheld LCR Meter LCRZDQ θ ESR Tester 100KHz USB 822C
$ 136.75
- Description
- Size Guide
Description
Note: we'll ship this item viaExpress mail service & ePacket
to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Italy, Spain, Malta, Norway, Sweden, Swiss, UK, Japan, Korea, Thailand, Indonesia, Malaysia, Philippine, Singapore.
Clients from other countries pls contact with us in advance to confirm the different shipping charges before you bid.
Features:
■ Basic measurement accuracy: 0.1%
■ Test signal frequency up to 100kHz
■ Measurement speed up to 10meas/sec
■ Large character display with bright white backlight
■ Ultra-low power consumption, battery-powered for 24 hours of continuous used
■ Automatic identification function (Ai)
■ Constant output impedance: 100 Ohm
■ Percentage display and 4-tolerance comparator: 1%, 5%,10% and 20%
■ Automatic Open/Short correction detection
■ Data hold, Max/Min/Average recording
■ Utility function configuration and current setup recovery after power-off
■ Standard
Mini-Usb
interface, SCPI compatible
Accessories:
7.2V NI-MH rechargeable battery, AC adapter, Short-circuit plate, 4-terminal Kelvin test leads, SMD 4-terminla Kelvin test Tweezers, PDF manual.
Specifications:
Function
Measurement Parameters
Primary Parameters: L / C / R / Z
Second Parameters: D / Q / θ / ESR
Equivalent Circuits
Serial, Parallel
Auto LCR Function
Manual/Auto
Ranging Mode
Auto
Test Terminals
2-terminal, 4-terminal,5-terminal
Measurement Speed
10meas/sec(Fast), 5meas/sec(Medium), 2meas/sec(Slow)
Correction
Short, Open
Tolerance Mode
1%, 5%, 10%, 20%
Input protection fuse
0.1A / 250V
Interface
Mini-USB(virtual serial port)
Test Signal
Signal Frequency
100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Test Signal Level
0.6Vrms
Output Impedance
100 Ω
Display
Display
LCD primary-secondary dual display
Backlight
Battery supply: when backlight is on, luminance is reduced by half 15s later and automatically turned off 30s later
Powered by adapter: backlight is on until manually turned off
Readings
Max. counts of primary parameter: 40,000; D / Q / θ Min. resolution of Secondary parameter:0.0001
Basic Accuracy
0.1%
Measurement Display Range
L
0.001uH --- 1000.0 H
C
0.001pF --- 20.000mF
R/Z
0.0001W --- 10.000MW
ESR
0.0000W -- 999.9W, resolution: 0.0001W
D
0.0000 -- 9.999, resolution: 0.0001
Q
0.0000 – 9999, resolution: 0.0001
θ
-179.9° -- 179.9°, resolution: 0.01°
Power Supply
Battery Model
7.2V Ni-MH 600mAH
rechargeable battery
AC Adapter
Input: 220V(1±10%), 50Hz(1±5%);Output: 9V DC
Operating Current
Max.: 28 mA, Typical: 25mA (1kHz ,100Ω load)
Standby(Power off) Current
Max.: 2uA
Battery Life
24 hours (Typical), based on backlight off and new fully charged Ni-MH battery
Charge Time and Current
Continuous charge time: Max. 80min
Charging current: Max. 150mA
Auto Power Off
5min, 15min, 30min, 60min, OFF available
Battery Capacity indicate
Real-time display on LCD
General
Operation Condition
Temperature
0°C -- 40°C
Relative Humidity
≤ 90% R.H.
Weight
460g
Dimensions (H
x W
X
D)
193mm x 92mm
X
44mm
Safety and EMC compliance
IEC 61010-1:2001; IEC 61326-2-1:2005